RSNU – New Construction/Replacement PTAC – Hydronic

Product Info

Ice Air RSNU line for new construction offers a durable, whisper-quiet solution with the highest energy efficiency available through the use of R32 Green refrigerant. The RSNU incorporates advanced features that comply with LEED criteria and prioritizes energy savings, making it an ideal addition to new buildings. The RSNU’s durable, user-friendly design is suited to a wide variety of applications, providing balanced air flow and easily programmable settings.

Category: New Construction PTAC

Products: 5RSNU07, 5RSNU09, 5RSNU13, 8RSNU09, 8RSNU13, 8RSNU18

See all PTAC Products PTAC Accessories Thermostat Options

Ice Air - Product - PTAC - RSNU - New Construction - Hydronic

Specifications

SERIES MODEL # 5RSNU07 5RSNU09 5RSNU13 8RSNU09 8RSNU13 8RSNU18
Cooling Capacity1 (BTU/h) 8,300 9,000 11,500 9,600 11,900 16,600
Sensible Cooling Capacity1 (BTU/h) 6,600 7,200 9,200 7,700 9,500 11,600
EER 11.6 11.4 10.6 11.2 11.0 9.5
Heating Capacity – Hot Water2 (BTU/h) 16,500 16,500 16,500 16,500 16,500 19,400
Heating Capacity – Steam3 (BTU/h) 18,700 18,700 18,700 18,700 18,700 20,200
Voltage 115 115 115 208/230 208/230 208/230
Cooling Mode Current (A) 6.2 6.9 9.4 4.1 5.2 8.4
Cooling Mode Power (W) 716 789 1,085 857 1,082 1,747
MCA 8.5 9.6 12.1 5.3 6.6 9.0
MOCP 15 15 15 15 15 15
Airflow AC High Speed (CFM) 380 380 400 380 400 540
Airflow AC Low Speed (CFM) 300 300 350 300 350 450
Airflow Outside (CFM) 60 60 60 60 60 60
Airflow Extra Outside (CFM) 110 110 110 110 110 110
Weight Net/Ship (lbs) 130/141 134/145 134/145 134/145 134/145 137/148
SPECIFICATION NOTES:
1. Cooling mode performance ratings are in compliance with AHRI standard 310/380 and CSA standard 744.
2. Hot water heating capacity rated @ EAT = 65 °F, EWT=200 °F, Flow Rate = 2GPM
3. Steam heating capacity rated @ EAT = 65 °F, Inlet Steam Pressure = 2 PSIG
4. Performance data based on R32 green refrigerant.


IMPORTANT: Additional voltages and alternate electric heat and heat pump options are available. For performance data and other available options please consult factory. Accessories are optional. Deviations from standard accessories may affect performance; louver requires 70% free area per original OEM specification; room enclosures must provide sufficient return air, free flowing supply air and must be properly sealed to prevent air recirculation; any non-standard components or accessories must be reviewed and approved by Ice Air or approved distributor.